Test Case 20

Test Case 20 is based on Test Case 2 and checks for repurposing of conversion facilities, including repurposing factors. Relevant sets and parameters can be seen from the tables below. In addition, tests are listed and illustrated.

Sets

Set NameSet Value
$\mathcal{A}$$\{DEU\_to\_DEU\}$
$\mathcal{AC}$$\begin{aligned} \{(DEU\_to\_DEU, CNG), \\ (DEU\_to\_DEU, GH2), (DEU\_to\_DEU, NH3)\} \end{aligned}$
$\mathcal{C}$$\{CNG,GH2,NH3\}$
$\mathcal{DSB}$$\{Block 1\}$
$\mathcal{I}$$\{Electricity\}$
$\mathcal{IOB}$$\{Block 1\}$
$\mathcal{M}$$\{OnlyTimeStep\}$
$\mathcal{N}$$\{DEU\}$
$\mathcal{O}$$\{RES\}$
$\mathcal{P}$$\{P\_DEU\}$
$\mathcal{RA}$
$\mathcal{RS}$
$\mathcal{RV}$
$\mathcal{S}$
$\mathcal{T}$$\{T\_DEU\}$
$\mathcal{V}$$\{V\_DEU\}$
$\mathcal{VT}$$\{(GH2,CNG),(GH2,NH3)\}$
$\mathcal{Y}$$\{2020,2021\}$

Parameters

Parametery=2020y=2021
$\frac{1}{ | \Delta |_{y}}$$1$$1$
${1}^{NC}_{T\_DEU,DEU,CNG}$$0$$0$
${1}^{NC}_{T\_DEU,DEU,GH2}$$0$$0$
${1}^{NC}_{T\_DEU,DEU,NH3}$$0$$0$
$r_{y}$$1$$1$
$d_{OnlyTimeStep}$$1$$1$
$c^{P}_{P\_DEU,GH2,RES,y}$$0.0$$0.0$
$c^{P}_{P\_DEU,NH3,RES,y}$$0.1$$0.1$
$c^{P}_{P\_DEU,CNG,RES,y}$$0.0$$0.0$
$c^{\Delta P}_{P\_DEU,GH2,RES,y}$$10$$10$
$c^{\Delta P}_{P\_DEU,NH3,RES,y}$$10$$10$
$c^{\Delta P}_{P\_DEU,CNG,RES,y}$$10$$10$
$fi^{P}_{GH2,Electricity,RES}$$1$$1$
$fi^{P}_{NH3,Electricity,RES}$$1$$1$
$fi^{P}_{CNG,Electricity,RES}$$1$$1$
$L^{P}_{GH2,RES}$$50$$50$
$L^{P}_{NH3,RES}$$50$$50$
$L^{P}_{CNG,RES}$$50$$50$
$\Lambda^{P}_{P\_DEU,GH2,RES,y}$$10$$10$
$\Lambda^{P}_{P\_DEU,NH3,RES,y}$$0$$0$
$\Lambda^{P}_{P\_DEU,CNG,RES,y}$$0$$0$
$\Lambda^{I}_{P\_DEU,Electricity,Block 1,y}$$10$$10$
$\Omega^{I}_{P\_DEU,Electricity,Block 1,y}$$0$$0$
$c^{\Delta^{I}}_{P\_DEU,Electricity,Block 1,y}$$0$$0$
$\Lambda^{T}_{T\_DEU,DEU,GH2,RES,y}$$10$$10$
$\Lambda^{T}_{T\_DEU,DEU,NH3,RES,y}$$10$$10$
$\Lambda^{T}_{T\_DEU,DEU,CNG,RES,y}$$10$$10$
$\Omega^{P}_{P\_DEU,GH2,RES,y}$$10$$10$
$\Omega^{P}_{P\_DEU,NH3,RES,y}$$10$$10$
$\Omega^{P}_{P\_DEU,CNG,RES,y}$$10$$10$
$fi^{V}_{GH2,CNG}$$1$$1$
$fi^{V}_{GH2,NH3}$$1$$1$
$l^{A}_{DEU\_to\_DEU,GH2}$$0$$0$
$l^{A}_{DEU\_to\_DEU,NH3}$$0$$0$
$l^{A}_{DEU\_to\_DEU,CNG}$$0$$0$
$c^{V}_{V\_DEU,GH2,CNG,y}$$0.1$$0.1$
$c^{V}_{V\_DEU,GH2,NH3,y}$$0.05$$0.05$
$c^{\Delta V}_{V\_DEU,GH2,CNG,y}$$10$$10$
$c^{\Delta V}_{V\_DEU,GH2,NH3,y}$$10$$10$
$c^{\Delta^{RV}}_{V\_DEU,GH2,CNG,GH2,NH3,y}$$0.025$$0.025$
$f^{RV}_{GH2,CNG,GH2,NH3}$$0.5$$0.5$
$\Lambda^{V}_{V\_DEU,GH2,CNG,y}$$10$$10$
$\Lambda^{V}_{V\_DEU,GH2,NH3,y}$$0$$0$
$L^{V}_{GH2,CNG}$$10$$10$
$L^{V}_{GH2,NH3}$$10$$10$
$c^{A}_{DEU\_to\_DEU,GH2,y}$$0$$0$
$c^{A}_{DEU\_to\_DEU,NH3,y}$$0$$0$
$c^{A}_{DEU\_to\_DEU,CNG,y}$$0$$0$
$c^{\Delta A}_{DEU\_to\_DEU,GH2,y}$$0$$0$
$c^{\Delta A}_{DEU\_to\_DEU,NH3,y}$$0$$0$
$c^{\Delta A}_{DEU\_to\_DEU,CNG,y}$$0$$0$
$\Lambda^{A}_{DEU\_to\_DEU,GH2,y}$$0$$0$
$\Lambda^{A}_{DEU\_to\_DEU,NH3,y}$$0$$0$
$\Lambda^{A}_{DEU\_to\_DEU,CNG,y}$$0$$0$
$L^{A}_{GH2}$$50$$50$
$L^{A}_{NH3}$$50$$50$
$L^{A}_{CNG}$$50$$50$
$c^{I_{l}}_{P\_DEU,Electricity,Block 1,OnlyTimeStep,y}$$0.3$$0.3$
$c^{I_{q}}_{P\_DEU,Electricity,Block 1,OnlyTimeStep,y}$$1$$1$
$av^{I}_{P\_DEU,Electricity,Block 1,OnlyTimeStep}$$1$$1$
$\alpha^{D}_{DEU,GH2,Block 1,OnlyTimeStep,y}$$0$$0$
$\beta^{D}_{DEU,GH2,Block 1,OnlyTimeStep,y}$$0$$0$
$\alpha^{D}_{DEU,NH3,Block 1,OnlyTimeStep,y}$$0$$2$
$\beta^{D}_{DEU,NH3,Block 1,OnlyTimeStep,y}$$0$$-1$
$\alpha^{D}_{DEU,CNG,Block 1,OnlyTimeStep,y}$$2$$0$
$\beta^{D}_{DEU,CNG,Block 1,OnlyTimeStep,y}$$-1$$0$

Test Criteria

ExpressionResult y=2020Result y=2021
$\tilde{P}^{T \rightarrow D}_{DEU,GH2,Block 1,OnlyTimeStep,y}$$0.00$$0.00$
$\tilde{P}^{T \rightarrow D}_{DEU,NH3,Block 1,OnlyTimeStep,y}$$0.00$$1.50$
$\tilde{P}^{T \rightarrow D}_{DEU,CNG,Block 1,OnlyTimeStep,y}$$1.25$$1.50$

Graphical Solution

Marginalized Provision Costs and Prices

GH2 2020

test_case_20a_graphic

GH2 2021

test_case_20b_graphic

NH3 2020

test_case_20c_graphic

NH3 2021

test_case_20d_graphic

CNG 2020

test_case_20e_graphic

CNG 2021

test_case_20f_graphic